The two-wire decoder version of Hunter's most powerful commercial controller
ACC-99D uses two-wire decoders to control up to 99 stations without giving up the arsenal of features provided by the ACC. Operating large numbers of valves over long distances, the ACC99D decoder controller takes full advantage of the powerful ACC feature set. Since it's two-wire powered, it also saves copper wire, simplifies troubleshooting, permits rapid addition of new stations, minimizes trenching, and permits remote sensor monitoring over the two-wire path.
|
ACC DECODER CONTROLLER MODELS ACC-99D - 2-Wire Decoder Controller with 99 station capacity, wall mount metal cabinet ACC-99DPP - 2-Wire Decoder Controller with 99 station capacity, plastic pedestal ICD-100 - Single-station decoder with surge suppression and ground wire ICD-200 - Two-station decoder with surge suppression and ground wire ICD-400 - Four-station decoder with surge suppression and ground wire ICD-600 - Six-station decoder with surge suppression and ground wire ICD-SEN - Two input sensor decoder with surge suppression and ground wire IDWIRE1 - 14 AWG/1.6 mm dia. decoder wire (up to 10,000 ft./3 km) IDWIRE2 - 12 AWG/2mm dia. decoder wire (up to 15,000 ft./4.5 km) HFS - Hunter flow sensor, requires the use of an FCT-xxx ACC-PED - Metal Pedestal for use with ACC-99D DIMENSIONS • ACC-99D Cabinet : 12 3/8" H x 15 1/2" W x 6 7/16" D (31.4 cm H x 39.4 cm W x 16.4 cm D) • ACC-99D Metal Pedestal: 36 1/8" H x 15 1/2" W x 5" D (91.5 cm H x 39.4 cm W x 12.7 cm D) • ACC-99D Plastic Pedestal: 38 3/8" H x 21 9/16" W x 15 7/8" D (97.5 cm H x 54.6 cm W x 40.3 cm D) • Decoders: ICD-100, 200, ICD-SEN - 3 5/8" H* x 1 1/2" W x 1/2" D (92 mm H* x 38 mm W x 12.7 mm D) ICD-400, 600 - 3 5/8" H* x 1 3/4" W x 1 1/2" D (92 mm H* x 46 mm W x 38 mm D) • Wire leads (all) - 18" L, 18 AWG dia. (46 cm L, 1 mm dia.) *Not including wire leads. SPECIFICATIONS & FEATURES • Transformer Input: 120/230VAC, 50/60 Hz, 2A max at 120V, 1A max at 230V. • Transformer output: 24VAC, 4A, @ 120VAC • Decoder Line (path) output: 34V peak-to-peak • Decoder Power draw: 40 mA per active output • Solenoid capacity: 2 standard 24 VAC Hunter solenoids per output within 100 ft./33 m runs, up to 14 solenoids max simultaneous (includes dual P/MV outputs) • Wiring, Decoder to solenoid: standard pair 18 AWG/1 mm to 100 ft./33 m (twisted improves surge resistance) • 6 two-wire output paths to field decoders • Two-way confirmation of decoder activation • Two-way monitoring of sensor connections (ICD-SEN) • Diagnostic LEDs with line status, signal activity, decoder and status • Programmable decoder station IDs (from controller panel) ACC-99D Decoder Systems include all standard features of the ACC controller, including: • 6 automatic programs, with 4 custom manual (auxiliary) programs • Dual pump/master valve outputs programmable by station • 1 flow meter (diagnostics to station level) and up to 4 sensor inputs (programmable to program level) • Programmable overlap or SmartStack by program with simultaneous station groups. • Seasonal adjust, 0 to 300% in 1% increments by program • Flow learning mode by station with programmable alarm thresholds • Station run times up to 6 hours with programmable delay between stations (up to 4 hours) • Self-diagnostic circuit breaker skips shorted stations and continues watering • SmartPort equipped for wireless remote control • Test program feature allows for quick system checks • IMMS 2.0 central system compatible • Upgrade to "smart" weather based watering with Solar Sync Sensor • Real-time Flow Monitoring capability built in, with actual flow histories (in GPM or metric) available when connected to Hunter HFS or other compatible flow meters. • Flow-learning mode by station, with station-level diagnostics and alarm shutdowns. • Easy Retrieve backup feature can restore schedules, run times, names and other settings to a saved setup
|